服务器ipmitool管理工具
#ipmitool -I lanplus -H 192.168.15.102-U lenovo -P lenovo power status’联想的ipmi配置
#ipmitool -I lanplus -H 10.11.13x.xx-U user -P password power status/on/off
ipmitools工具下载。
华为服务器:IPMI使用
#ipmitool -I open chassis status
System Power : on
Power Overload : false
Power Interlock : inactive
Main Power Fault : false
Power Control Fault: false
Power Restore Policy : always-on
Last Power Event :
Chassis Intrusion : inactive
Front-Panel Lockout: inactive
Drive Fault : false
Cooling/Fan Fault : false
Front Panel Control: none 华为服务器检测
#ipmitool -H 192.168.113.3 -U root -P Huawei12#$ -I open chassis status
System Power : on
Power Overload : false
Power Interlock : inactive
Main Power Fault : false
Power Control Fault: false
Power Restore Policy : always-on
Last Power Event :
Chassis Intrusion : inactive
Front-Panel Lockout: inactive
Drive Fault : false
Cooling/Fan Fault : false
Front Panel Control: none modprobe ipmi_devintf
modprobe ipmi_si
modprobe ipmi_msghandler
modprobe ipmi_watchdog
modprobe ipmi_poweroff
页: